Micronics Ltd
The world's easiest to use flow meter Micronics
 
 
   
  Spacer
 


+44(0)1628810456
  Flow Meters
  Heat+Energy meters
  Complementary Product+Telemetry
 
 
 
     
     
 
 
 
 
 
 
   
 
   
 
 
  U2000
• For “clean” liquid
monitoring
• To suit pipes 13mm-
5000mm
• Non invasive sensing
• Easy to use




 

  CalecST
 
 
• Used in conjunction with the U2000 for energy measurements
• PT100 clamp-on or PT500 insertion probes
• Choice of output options
• LCD screen
• Quick to set up and easy to use
 
  U100
• For “clean” liquid
monitoring
• To suit pipes 50mm-
200mm
• Non invasive sensing
• Software based setup-easy to use



 

  CalecST
 
 
• Used in conjunction with the U100 for energy measurements
• PT100 clamp-on or PT500 insertion probes
• Choice of output options
• LCD screen
• Quick to set up and easy to use

 
     
   
Compatible with any flow meter with a pulse output.
Quick and easy setup.
Choice of outputs- Pulses or 4-20mA including Mbus or Lon communication
Kwh Total, instant energy, Volume and temperature readings.
 

Brochure
Quick Start

Manual


         
   
 

Sensor probes :- 4 wire PT100 clamp-on 150mm or 2 wire 50mm PT500 insertion probes.
Transducer temperature Range:-
-0°C to +180°C.
Power:-
240Vac or vis Mbus, Battery powered option available.
Options:-
Heat carrier medium type to order, supplied as standard for water

Display:- LCD.
Units:-
Selectable, volume, Delta T, Hot and Cold temperature, Kwh Total, Instant energy..
Outputs :-
Pulse Kwh+Pulse M³ with Mbus output,
4-20mA x 2 assignable with Mbus output
.
Programming:-
No programming required- set and forget.


   

 
     
   
Simple set-up menu.
Current, pulse or set point outputs.
High temp. Transducers-option.
Energy meter version.
 
 

Brochure
Quick Start

Manual


         
 

 





 

Pipe Range:- 13mm to 5000mm ID
Electronics:- ABS housing with clear
polycarbonate front panel waterproof
and dustproof to IP66.

Temperature Range:-
+5°C to + 60°C.
Keypad:- 16 key panel for set up,
Diagnostics. Access password protected

Display:-
2 x 16 LCD. Backlit.
Power Input:-
110/240VAC +/-10%
50/60Hz @ 50watts 24VDC +/- 10%, 6
watts.

Outputs:-
Flow proportional 0/4 – 20mA
Active opto isolated into 500ohms. Bidirectional, Pulse or set point relay. 5A- SPDT. Selectable rate and totaliser to 12 digits.

Transducers:- A, B, C or D sensors
factory selected based on flow rate.
Range:- 0.5m/sec to 10m/sec.

Operating Temp.
–20°C to +125°C
Optional hi-temp to 175°C

Accuracy:-
< +/- 3% of reading or +/-
0.05/sec whichever is the greater

Repeatability:-
< +/- 1% with unchanged
Transducer positions.

 

   

 
     
 
   
Application specific.
Pre-calibrated and scaled.
No mechanical adjustment required.
 

Brochure

Manual


             
   
 

Electronics:- Cast aluminium housing 150x90x60mm,
Waterproof, Dust proof to IP54.

Operating Temp Range:-
+5°C to +60°C.
Storage Temp Range:-
-5°C to + 65°C.
Power:-
90-260VAC, 50/60Hz or 20-28VDC @5W.
Outputs:-
0/4-20mA, Pulse (1per sec max) RS 232 Opto Isolated. Diagnostics and reconfiguration via
RS232 port using installed GUI software.

Pipe Range:-
50mm to 200mm ID.
Application Temp Range:-
- 20°C to +80°C.
Flow Range:-
up to 24L/sec in 100mm pipe.
Minimum flow:-
0.05m/sec.
Typical Accuracy:-
+/-1 to 3% of reading or 0.1 L/sec whichever is the greatest.
Repeatability:-
+/- 1% with unchanged sensor position.
Linearity:-
+/-1% of calibrated range.

 

 

 
   

   



Micronics Ltd, Knaves Beech Business Centre, Davies Way, Loudwater, High Wycombe, Bucks, HP10 9QR, United Kingdom
Tel : +44 (0)1628 810456 Fax : +44 (0)1628 531540