AVFM-II |
 |
|
|
• For part filled pipe and
open channel monitoring
• 50000 point logger and software
• Streamlined sensor for
invasive measurement
• Easy to use
|
|
|
| |
| |
DFM-4.0 |
 |
|
|
• For “dirty” liquid
monitoring
• To suit pipes 13mm-
4500mm
• Non invasive sensing
• Easy to use
|
|
|
| |
| |
DFS-II |
 |
|
|
• For “dirty” liquids
• Adjustable relay/
setpoint outputs
• Non invasive sensing
• Easy to use
|
|
|
| |
| |
OCF-II |
 |
|
|
• For open channel
monitoring
• 50000 point logger
and software
• Versatile choice of
channel types
• Easy to use
|
|
|
| |
| |
LIT-25 |
 |
|
|
• For level
monitoring
• Versatile choice of
sensor types
• Easy to use
|
|
|
|
| |
| |
SLT-32 |
 |
|
|
• For open channel and level
monitoring
• 50000 point logger option
and software
• Versatile choice of
channel types
• Easy to use
|
|
|
|
| |
| |
MFS-100 |
 |
|
|
• For indicating the presence of flow in closed pipes
• Works on many types of liquids
• Easy to use simple to set correct sensitivity
|
|
|
|
| |
| |
TFT-32 |
 |
|
|
• For indicating the presence of flow in closed pipes
•Combine up to 32 units for site wide monitoring
• Easy to use
|
|
|
|
| |
| |
PSL |
 |
|
|
• Monitors and controls multiple pumps
• Combined with software for ease of use
|
|
|
|
|
|
|
| |
|
| |
Enclosure:- Watertight and dustproof (IP66).
Power Input:- 100-130VAC and 200-250VAC, 50/60HZ., 7.5 watts 12VDC or 24VDC.
Outputs:- 2x Isolated 4-20mA into 1000 ohm load.Programmable for Flow, Head or Velocity. RS 232 Option Serial and Windows Software.
Relays:- 3 x form ‘C’ dry contacts rated 5 amp SBDT Programmable for Flow Proportional pulse (sampler/totalizer) flow and/or level alarm.
Velocity Range:- 0.03 to 6.2m/sec
Level Range:- Minimum Head 25mmto maximum head 4.5m.
|
Accuracy:-
Level:- 0.25% of Range,
Velocity:- +/-2% of Reading,
Linearity and Repeatability:- +/- 0.1%. |
| |
|
|
| |
|
|
| |
|
| |
Pipe Range:- >13mm up to 4.5m
Power Input:- 100 –260VAC, 50/60Hz, 12-28VDC 5watts max.
Flow Rate Range:- 0.08m/s to 12m/s
Accuracy:- +/-2% of full scale. Requires solids
or bubbles of minimum size 100 microns,
minimum concentration 75ppm.
Repeatability:- +/- 0.1%.
Linearity:- +/-0.5% of full scale.
Display:- Large 4 Digit LCD for programmable output in engineering units.16-digit alpha numeric for Totaliser, Menu, status, signal strength.
Output:- Isolated 0/4 –20mA(1000ohm load max.) 3-5amp rated SPDT relays, programmable flow
alarms and/or proportional pulse. Adjustable
sensitivity and damping. |
Electronics Operating Temp:- -23°C to + 60°C.
Sensor Operating Temp:- -40°C to + 90°C.
Options:- Intrinsic safety barriers, high temp to 150°C, ISE insertion and dual head types for special applications. Enclosure heater controlled to maintain temp. at 40°C
Data logger:- 50,000 points via RS 232 output with Windows software. |
| |
|
|
| |
|
|
| |
|
| |
|
Electronics:- Wall
mounting 175x125x
75m m.
Power Input:- 100 – 130VAC, 50/60Hz, 4.2watts.
200 – 260VAC, 50/60Hz, 4.8watts. Optional
24VDC, 3.6watts. Surge protection on power Input.
Output:- 5amp relay, DPDT.
Set Point:- On/Off adjustment – 0.1 to 3m
per sec.
Time delay:- Switch selectable.
Failsafe Mode:- Switch selectable.
Indication:- Relay status and signal strength LED’s.
Pipe Range:- 12.5mm ID to 4.5m ID.
Sensor cable:- Surge protected, 5m-Shielded Coax
Optional:- 15m.
Hazardous Locations:- Intrinsic safety
Barriers option. |
|
|
|
|
| |
|
|
|
| |
|
| |
Enclosure:- Polycarbonate (IP66). Shatterproof clear Front Panel.
Power:- 100-130VAC/200-260VAC, 50/60HZ & 5watts max.
Option:- 12VDC or24VDC.
Outputs:- 4-20ma isolated into 1000ohm load. 3x control Relays Form "C" dry contacts rated 5amps SPDT. Isolated RS232 for cable transfer to PC or Dial up connection. Programmable baud rate from 1200 to 19200. |
Sensor Specification:- Maximum range: 3.66m.
Dead band:- Programmable. Minimum 200mm.
Beam Angle:- 8°.
Operating Frequency:- 92KHz. Exposed Matl. CBVC. Temperature compensated.
Max Pressure:- 1.35bar. |
| |
|
|
| |
|
|
|